Dialysis Care Support
Dialysis Water Treatment

CISTY 500–5000 Full Automatic RO Systems

Compact full automatic dialysis RO systems with capacities from 500 to 5000 litres/hour, advanced pretreatment, automatic raw-water and permeate-quality monitoring, and single-pass or double-pass design with heat-disinfection support.

Output water qualityAAMI / ISO 23500:2019
ProductCISTY 500 Enquire Now

CISTY 500

Compact full automatic RO plant from the CISTY 500–5000 range, engineered for dialysis water treatment with programmable pretreatment, automatic water-quality monitoring, water-saving technology and heat-disinfection support.

Capacity500 litres/hour
Input WaterTDS up to 2000
OutputAAMI / ISO 23500:2019
DescriptionCompact full automatic RO plant from the CISTY 500–5000 range, suitable for dialysis water-treatment applications and configurations up to 20 dialysis machines.
Capacity500 litres/hour
Input WaterMaximum TDS up to 2000
PretreatmentProgrammable auto-washable multimedia, iron, charcoal and softener vessel with 10 and 5 micron cartridges
Raw Water & Permeate QualityAutomatic check of consumption, temperature, pressure and TDS
Voltage230V / 440V, 50Hz, AC single phase / three phase
Raw Water Pressure1.5–4 bar
Raw Water TemperatureUp to 45°C
MembranePolyamide Dupont / Hydranautics membrane with auto-flush facility for bacterial-growth protection
Permeate TankStainless Steel 316 / 304 grade
Heater TankHeating up to 90°C for total loop-line heat disinfection
Endotoxin Filter & UVInbuilt
Water-Saving TechnologyYes
Output WaterAAMI / ISO 23500:2019 Standard
DesignMicroprocessor-based double-pass / single-pass system with heat-disinfection system
ProductCISTY 1000 Enquire Now

CISTY 1000

Compact full automatic RO plant from the CISTY 500–5000 range, engineered for dialysis water treatment with programmable pretreatment, automatic water-quality monitoring, water-saving technology and heat-disinfection support.

Capacity1000 litres/hour
Input WaterTDS up to 2000
OutputAAMI / ISO 23500:2019
DescriptionCompact full automatic RO plant from the CISTY 500–5000 range, suitable for dialysis water-treatment applications and configurations up to 20 dialysis machines.
Capacity1000 litres/hour
Input WaterMaximum TDS up to 2000
PretreatmentProgrammable auto-washable multimedia, iron, charcoal and softener vessel with 10 and 5 micron cartridges
Raw Water & Permeate QualityAutomatic check of consumption, temperature, pressure and TDS
Voltage230V / 440V, 50Hz, AC single phase / three phase
Raw Water Pressure1.5–4 bar
Raw Water TemperatureUp to 45°C
MembranePolyamide Dupont / Hydranautics membrane with auto-flush facility for bacterial-growth protection
Permeate TankStainless Steel 316 / 304 grade
Heater TankHeating up to 90°C for total loop-line heat disinfection
Endotoxin Filter & UVInbuilt
Water-Saving TechnologyYes
Output WaterAAMI / ISO 23500:2019 Standard
DesignMicroprocessor-based double-pass / single-pass system with heat-disinfection system
Product CISTY 1500 Enquire Now

CISTY 1500

Compact fully automatic RO plant with a permeate-water capacity of 1500 litres/hour, suitable for up to 30 dialysis machines. Features include programmable pretreatment, automatic raw-water and permeate-quality monitoring, and a microprocessor-based single-pass or double-pass design with heat disinfection.

Capacity 1500 litres/hour
Dialysis Machines Up to 30
Output AAMI / ISO 23500:2019
Description Compact fully automatic RO plant suitable for up to 30 dialysis machines
Capacity 1500 litres/hour of permeate water
Design Microprocessor-based double-pass / single-pass system with heat disinfection
Pretreatment Programmable auto-washable multimedia, iron, charcoal and softener vessels with 10 and 5 micron cartridges
Raw Water & Permeate Quality Automatic monitoring of consumption, temperature, pressure and TDS
Voltage 440V, 50Hz, AC three phase
Raw Water Pressure 2.5–4 bar
Raw Water Temperature Up to 45°C
Membrane Polyamide DuPont / Hydranautics membrane with an auto-flush facility for bacterial-growth protection
Permeate Tank Stainless steel 316 / 304 grade
Heater Tank Heating up to 90°C for total loop-line heat disinfection
Endotoxin Filter & UV Inbuilt
Water-Saving Technology Yes
Output Water AAMI / ISO 23500:2019 standard, as stated in the product brochure
ProductCISTY 2000 Enquire Now

CISTY 2000

Compact full automatic RO plant from the CISTY 500–5000 range, engineered for dialysis water treatment with programmable pretreatment, automatic water-quality monitoring, water-saving technology and heat-disinfection support.

Capacity2000 litres/hour
Input WaterTDS up to 2000
OutputAAMI / ISO 23500:2019
DescriptionCompact full automatic RO plant from the CISTY 500–5000 range, suitable for dialysis water-treatment applications and configurations up to 20 dialysis machines.
Capacity2000 litres/hour
Input WaterMaximum TDS up to 2000
PretreatmentProgrammable auto-washable multimedia, iron, charcoal and softener vessel with 10 and 5 micron cartridges
Raw Water & Permeate QualityAutomatic check of consumption, temperature, pressure and TDS
Voltage230V / 440V, 50Hz, AC single phase / three phase
Raw Water Pressure1.5–4 bar
Raw Water TemperatureUp to 45°C
MembranePolyamide Dupont / Hydranautics membrane with auto-flush facility for bacterial-growth protection
Permeate TankStainless Steel 316 / 304 grade
Heater TankHeating up to 90°C for total loop-line heat disinfection
Endotoxin Filter & UVInbuilt
Water-Saving TechnologyYes
Output WaterAAMI / ISO 23500:2019 Standard
DesignMicroprocessor-based double-pass / single-pass system with heat-disinfection system
Facebook Instagram Telegram Twitter YouTube